Generator - it is important to keep the windings dry to prevent corrosion and ensure a shorter starting time. Dry air can also supplement generator heaters.
Condenser - must be kept dry after flushing to allow recoating of water boxes and tube plates.
Re-heater - tubes are thinner than super heater tubes and more susceptible to corrosion. Inter-granular attacks on austenic stainless steel can be minimised using dry air.
Feed & Condensate pipes - important to eliminate internal corrosion on pipes as oxides can contaminate feed water.
Boiler - surface temperatures of fireside boiler tubing drop below the dew-point and form condensate. The condensate reacts with sulphurous parts of the ash and acid deposits and hydrolyses, forming a highly acidic solution. The end result is rapid, localized attack of the metal surface.
Reactor vessel - Where access is
required, dry air is required to purge out CO2, eliminate corrosion and to dry the graphite prior to refilling with CO2